Re: Resync Every Sunday | |
| [Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index] |
|
On 02/07/2012 22:30, Keith Keller wrote:
Unfortunately it is not possible for me to upgrade. Would just simply replacing the raid-check script work? Or is that dangerous?On 2012-07-02, Larkin Lowrey<llowrey@xxxxxxxxxxxxxxxxx> wrote:That is not the correct logic so your script is out of date. I would recommend updating your mdadm package via yum. My CentOS 6.2 install has the correct logic in /usr/sbin/raid-check, which is the new location for the script. The RPM I have installed is mdadm-3.2.2-9.el6.x86_64.The OP is on CentOS 5, where the latest package is 2.6.9-3. I am not sure whether that version has the bug fix. --keith
Thanks -- To unsubscribe from this list: send the line "unsubscribe linux-raid" in the body of a message to majordomo@xxxxxxxxxxxxxxx More majordomo info at http://vger.kernel.org/majordomo-info.html
![]() |
![]() |