Re: [PATCH] NET: bcm63xx_enet: move phy_(dis)connect into probe/remove

[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

On Wed, 2012-04-18 at 21:30 +0200, Jonas Gorski wrote:
> 
> The phy state machine will start in PHY_READY after phy_connect, which
> will result in NOPs, so no call to bcm_enet_adjust_phy_link() after
> _probe() and before _open(). The state machine starts doing real work
> only after calling phy_start(), which happens only after the dma
> register accesses in open(). So no race here. 

If I read the phylib code correctly, after phy_connect() the phy is in
READY state, and you can access it via ethtool.

-- 
Maxime


--
To unsubscribe from this list: send the line "unsubscribe netdev" in
the body of a message to majordomo@xxxxxxxxxxxxxxx
More majordomo info at  http://vger.kernel.org/majordomo-info.html


[Linux Kernel Discussion]     [Ethernet Bridging]     [Linux Wireless Networking]     [Linux Bluetooth Networking]     [Linux Networking Users]     [VLAN]     [Git]     [IETF Annouce]     [Linux Assembly]     [Security]     [Bugtraq]     [Photo]     [Singles Social Networking]     [Yosemite Information]     [MIPS Linux]     [ARM Linux Kernel]     [ARM Linux]     [Linux Virtualization]     [Linux Security]     [Linux IDE]     [Linux RAID]     [Linux SCSI]     [Free Dating]